Glove Testing in Isolators and RABS: Overview
Glove testing in isolators and Restricted Access Barrier Systems (RABS) is critical in pharmaceutical and biotechnology manufacturing to maintain a sterile and contained environment. This testing is essential for contamination control, especially when working with hazardous, sterile, or highly sensitive materials. The gloves in these systems are a barrier to prevent contamination while allowing operators to perform tasks in a controlled environment.
This blog covers the following topics:
- Types of Gloves Used in Isolators and RABS
- Qualifications of Gloves for Isolators and RABS
- Regulatory Requirements for Glove Testing (FDA, Health Canada, MHRA, EMA, TGA, ANVISA, WHO)
- Step-by-Step Guide to Performing Glove Leak Testing
Depyrogenating Tunnels | Regulatory Requirements | GxP Cellators
Types of Gloves in Isolators and RABS
The gloves used in isolators and RABS must meet specific performance criteria to protect the operator and the product. The following types of gloves are commonly used:
1.1. Natural Rubber Latex Gloves
- Characteristics: Elastic, high tactile sensitivity, and good flexibility.
- Advantages: Comfortable and provides a good fit for operators requiring high dexterity.
- Disadvantages: It can cause latex allergies, especially in sensitive individuals.
- Use: It is less common today due to the risk of allergies, but it is still used in environments that require high flexibility and where non-hazardous materials are handled.
1.2. Nitrile Gloves
- Characteristics: Latex-free, resistant to punctures, chemicals, and oils.
- Advantages: Highly durable, chemical-resistant, and less likely to cause allergies than latex gloves.
- Use: This is the most commonly used glove type in isolators and RABS due to its versatility, strength, and reduced allergy risk.
1.3. Butyl Rubber Gloves
- Characteristics: Very resistant to chemicals, gases, and vapours but less flexible than nitrile or latex gloves.
- Advantages: Ideal for handling potent or hazardous substances.
- Disadvantages: Not as flexible, which can lead to discomfort or fatigue for the operator.
- Use: It is preferred in environments requiring high chemical resistance (e.g., handling cytotoxic drugs, solvents, or highly toxic substances).
1.4. Polyvinyl Chloride (PVC) Gloves
- Characteristics: Chemical resistant but less flexible and durable than nitrile or latex.
- Advantages: Cost-effective and resistant to specific chemicals.
- Disadvantages: Less comfort and dexterity compared to nitrile or latex gloves.
- Use: Suitable for less critical applications within the isolator or RABS environment.
1.5. Hypoallergenic Gloves
- Characteristics: Designed for individuals who are allergic to latex.
- Materials: Often made from nitrile, neoprene, or other synthetic materials.
- Use: It is necessary in environments where latex allergies are a concern, and it provides high strength and chemical resistance.
Qualifications of Gloves for Isolators and RABS
The gloves used in isolators and RABS must meet stringent qualification criteria to ensure they are suitable for maintaining a sterile environment. Key qualifications for gloves include:
2.1. Barrier Integrity
- Gloves must form a perfect barrier to microorganisms, chemicals, and hazardous materials.
- Testing Methods: Biological testing (e.g., ASTM F1671 for virus penetration) ensures the glove’s barrier properties are intact.
2.2. Puncture and Tear Resistance
- Gloves must withstand punctures, tears, and abrasions that could lead to loss of containment.
- Testing Methods: Puncture resistance tests (e.g., ASTM F1342) and tear resistance tests (e.g., ISO 13997) assess the gloves’ durability.
2.3. Tensile Strength and Elongation
- Gloves must have sufficient tensile strength to prevent tearing under stress and sufficient elongation to allow flexibility.
- Testing Methods: ASTM D412 measures tensile strength and elongation properties, ensuring gloves can stretch and bend without rupturing.
2.4. Chemical Compatibility
- Gloves must be chemically resistant to the substances handled within the isolator or RABS, including solvents, acids, and drugs.
- Testing Methods: ISO 374 for chemical resistance helps determine how well gloves withstand chemical exposure.
2.5. Sterility
- Gloves must be sterile when used in aseptic environments and remain sterile during isolation or RABS installation.
- Testing Methods: Sterility testing ensures gloves are free from contamination after sterilization, typically through gamma irradiation or ethylene oxide (EO) sterilization.
2.6. Fit and Comfort
- Gloves should fit properly to reduce operator fatigue and discomfort, which is crucial when wearing gloves for extended periods.
- Testing Methods: Gloves are often evaluated for ergonomics and comfort to ensure they don’t impair dexterity, and the fit is critical in preventing hand strain.
Regulatory Requirements for Glove Testing
Several regulatory bodies have specific requirements for glove testing in isolators and RABS. The guidelines ensure gloves meet safety, quality, and contamination control standards.
3.1. FDA (U.S. Food and Drug Administration)
- 21 CFR Part 211: Requires validation of aseptic processing systems, including glove leak testing, to ensure sterility during manufacturing. Gloves must be tested for leak integrity to validate the isolator or RABS.
- USP <1116>: This chapter covers microbial control and recommends routine glove leak testing for aseptic processing validation.
3.2. Health Canada
- Health Canada follows GMP guidelines similar to those of the FDA. It requires manufacturers to validate the aseptic processing system and conduct regular glove leak tests to maintain a sterile environment.
3.3. MHRA (Medicines and Healthcare products Regulatory Agency – UK)
- EU GMP Annex 1 (2022): This annex outlines the requirements for manufacturing sterile medicinal products and mandates that gloves used in isolators and RABS undergo regular testing to ensure barrier integrity and containment.
3.4. EMA (European Medicines Agency)
- EU GMP Annex 1: The EMA requires routine testing of gloves in isolators and RABS as part of the process validation. The system must be capable of maintaining aseptic conditions, which includes the leak testing of gloves.
3.5. TGA (Therapeutic Goods Administration – Australia)
- Like the FDA and EMA, the TGA requires GMP compliance and mandates regular testing of gloves used in containment systems to ensure they meet required safety standards and prevent contamination.
3.6. ANVISA (Brazil)
- ANVISA’s regulations align with international standards, and gloves must be regularly tested to ensure they provide an effective barrier to contamination and maintain the integrity of aseptic processing systems.
3.7. WHO (World Health Organization)
- WHO GMP guidelines emphasize the importance of contamination control and include specific requirements for glove testing in aseptic processing environments, ensuring the gloves provide a sterile barrier and meet safety standards.
Step-by-Step Guide to Performing Glove Leak Testing
Glove leak testing is essential for maintaining the sterile integrity of isolators and RABS. Here’s a step-by-step guide on how to perform glove leak testing:
Step 1: Preparation
- Inspect the System: Ensure the isolator or RABS is set up and operated correctly. Clean all surfaces before initiating the leak test.
- Verify Glove Installation: Check that the gloves are properly installed in the glove ports and are free from visible defects (e.g., holes, tears).
- Ensure Equipment Calibration: All testing equipment (pressure sensors, mass spectrometers, ultrasonic sensors) is calibrated and functioning correctly.
Step 2: Select the Testing Method
Choose a testing method based on the sensitivity required and available equipment. Common methods include:
- Pressure Decay Test
- Vacuum Decay Test
- Helium Leak Detection
- Ultrasonic Leak Detection
Step 3: Perform the Leak Test
- Pressure Decay Test: Inflate the glove with air and monitor the pressure over time. A pressure drop indicates a leak.
- Vacuum Decay Test: Create a vacuum inside the glove and monitor for any rise in pressure, indicating air entering through a leak.
- Helium Leak Detection: Fill the glove with helium and use a mass spectrometer to detect helium escaping from the glove.
- Ultrasonic Leak Detection: Ultrasonic sensors detect high-frequency sound caused by air escaping from a leaking glove.
Step 4: Analyze Results
- If a leak is detected, the glove must be replaced immediately.
- Documentation: Record the results of the leak test, including:
- Type of test used.
- Results (pass or fail).
- Corrective actions taken (e.g., glove replacement).
Step 5: Documentation and Review
- Record all tests as part of the validation and qualification process. This ensures compliance with regulatory requirements and supports future audits.
- Regularly review testing data to ensure continuous compliance with GMP and regulatory standards.
Step 6: Replace or Repair Gloves
- If a glove fails the leak test, it should be replaced and retested to confirm its integrity before being returned to service.
- Ensure any failed gloves are properly disposed of to maintain a contamination-free environment.
Contact Us
GxP Cellators Consultants Ltd. is a well-regarded contract services organization that offers comprehensive Good x Practices (GxP) services in Manufacturing, Laboratory, Distribution, Engineering, and Clinical practices to a range of industries, including pharmaceuticals, biopharmaceuticals, medical devices, and cannabis. We work closely with our esteemed life sciences clients to assist them in establishing greenfield or brownfield projects, guiding them from the project stage to regulatory approval for their GxP sites.
Our team comprises highly qualified experts specializing in Good Manufacturing Practices (GMP), Good Laboratory Practices (GLP), Good Clinical Practices (GCP), Good Distribution Practices (GDP), Cleanroom Operations, and Engineering Operations. Our Subject Matter Experts (SMEs) undergo extensive training and possess the essential knowledge and skills to excel in their respective domains.
We also have a team of highly skilled validation specialists with expertise in equipment and utilities qualifications, computerized system validations (CSV), thermal validations, clean utilities validation, and cleanroom validations. If you need help preparing your facilities or site equipment, please don’t hesitate to contact us at .